Micelect SPB Sensor - Phased out - will be replaced with 5090483
Application:
The SPB sensor is designed for precise load monitoring in hydraulic elevators. Thgis sensor comes with cable connection.
Main Features:
- Automatic calibration without test weights
- Quick installation (approx. 5 minutes)
- Two programmable alarms: full load and overload
- Integrated display showing pressure in bar
- EEPROM memory for data storage
Electrical Characteristics:
- Power supply: 24–48 VDC
- Deactivation input: 24–230 VAC/DC
- Relay contacts: 250 VAC, 3 A
Mechanical Characteristics:
- Operating pressure: 100 bar
- Safe load: 150% of operating pressure
- Maximum overload: 200% of operating pressure
- Deformation under overload: <0.5 mm
- Hysteresis: <0.1% of operating pressure
- Total error: <3% of operating pressure
- Weight: 0.2 kg
Temperature Range:
- Operating temperature: -10 °C to +80 °C